NVIDIA/Mellanox Compatible 800GBASE-DR4 OSFP112 RHS/Flat Top 8x100G PAM4 Broadcom 3nm DSP 1310nm 500m SMF DOM MPO-12/APC Optical Transceiver Module for ConnectX-8 C8180 SuperNIC

$1,389.00

SKU: A345BCF4EF36

Product Highlights

  • 8×100G PAM4 electrical lanes and 4×200G PAM4 optical lanes, delivering an aggregate 800G data rate.
  • Equipped with a Broadcom 3nm DSP, with maximum power consumption of ≤15W.
  • Designed for 800G NVIDIA ConnectX-8 NIC-to-1.6T Ethernet switch interconnections in compatible network configurations.
  • Compliant with the OSFP MSA and applicable IEEE 802.3 specifications.
  • Class 1 laser safety (subject to product certification) and RoHS-compliant, lead-free construction.
  • DDM (Digital Diagnostic Monitoring) supported for real-time monitoring of key operating parameters.
  • 30-Day Free Return, 1-Year Free Replacement, 3-Year Warranty, and Lifetime After-Sales Technical Support.

NVIDIA/Mellanox Compatible 800GBASE-DR4 OSFP112 RHS Flat Top Transceiver for ConnectX-8 C8180 SuperNIC

The NVIDIA/Mellanox Compatible 800GBASE-DR4 OSFP112 RHS Flat Top Optical Transceiver Module is designed for high-speed connectivity between NVIDIA ConnectX-8 (CX8) 800G network interface cards and compatible next-generation Ethernet switches. Built in an OSFP112 Flat Top form factor, it integrates a Broadcom 3nm DSP to support high-speed signal processing while maintaining a maximum power consumption of 15W.

The module features an 8×100G PAM4 electrical interface and a 4×200G PAM4 optical interface, delivering an aggregate bandwidth of 800Gbps. Operating at a nominal wavelength of 1310nm, it supports parallel optical transmission over single-mode fiber (SMF) with a link distance of up to 500 meters. The MPO-12/APC interface provides the optical connection for compatible 800G DR4 links.

Designed primarily for ConnectX-8 OSFP 800G NIC applications, this transceiver enables connectivity between 800G server-side network interfaces and compatible 1.6T Ethernet switch platforms. Its electrical-to-optical lane-rate conversion architecture allows an 800G NIC to connect to a supported 1.6T switch port, helping network designers integrate existing 800G server connectivity into higher-capacity switching fabrics.

With its Broadcom 3nm DSP and OSFP112 Flat Top design, the O112-800G-DR4 is suitable for demanding AI data center networks, large-scale GPU clusters, and high-performance computing (HPC) environments. It provides a practical optical interconnect option for next-generation RoCE-based network architectures, including compatible NVIDIA B300 and GB300 NVL72 deployments.

Specifications

Part Number O112-800G-DR4 Vendor Name SFPPlaza
Form Factor OSFP112 Max. Data Rate 800Gbps
Wavelength 1310nm Max. Cable Distance 500m
Connector MTP/MPO-12 APC Media SMF
Transmitter Type 1310nm CW Laser + SiPh MZM Receiver Type PIN
Max. Power Consumption ≤15W Protocols 800G Ethernet Compliant
DDM/DOM Supported Commercial Temperature Range 15℃ to 70℃ (59°F to 158°F)
Modulation (Electrical) 8×106.25Gb/s PAM4 Modulation (Optical) 4×212.5Gb/s PAM4

Highlights

Purpose-Built for NVIDIA ConnectX-8 800G NIC Connectivity

  • ConnectX-8 NIC Integration: Designed for compatible NVIDIA ConnectX-8 OSFP 800G network interface cards, supporting high-bandwidth server-to-switch connectivity.
  • 800G NIC to 1.6T Switch Architecture: Enables an 800G ConnectX-8 NIC to connect to a compatible 1.6T Ethernet switch port, providing a migration path toward higher-capacity switching fabrics while retaining supported 800G NIC infrastructure.
  • Host-Specific Flat Top Design: The OSFP112 RHS/Flat Top housing is intended for compatible ConnectX-8 NIC cages and their associated thermal management systems.

Broadcom 3nm DSP for High-Density AI Networks

  • Advanced DSP Integration: The Broadcom 3nm DSP supports high-speed signal processing for demanding 800G electrical and optical interfaces.
  • Power-Conscious Deployment: A maximum power specification of 15W helps network designers plan power budgets and thermal requirements for high-density server connectivity.
  • High-Speed Lane Conversion: Supports the conversion between the NIC-side 8×100G electrical interface and the 4×200G optical interface required by this 800G architecture.

Designed for Next-Generation NVIDIA AI Infrastructure

  • NVIDIA B300 and GB300 NVL72 Networks: Suitable for compatible RoCE network architectures connecting GPU servers to high-capacity Ethernet switching infrastructure.
  • Large-Scale AI Training: Supports high-throughput communication fabrics for distributed training, GPU-to-GPU data exchange, and large-scale AI workloads.
  • HPC and Data-Intensive Computing: Provides an optical connectivity option for high-performance computing clusters, accelerated computing environments, and bandwidth-intensive data center applications.
  • Network Upgrade Flexibility: Helps operators integrate 800G server-side interfaces into supported 1.6T switch architectures, potentially reducing the need for immediate NIC replacement during network capacity upgrades.

100% Compatibility Validated for Arista, NVIDIA, Cisco & Broadcom RoCE Networks

SFPPlaza optical transceivers, AOCs, and DACs undergo rigorous compatibility and interoperability testing with leading RoCE networking platforms, including Arista 7060XE7 and 7060X6 Series data center switches, NVIDIA Spectrum-4 SN5000 Series switches, Cisco N9100 and Nexus 9364E-SG2 Series switches, and Broadcom BCM57708 and BCM957608 NICs. Designed for high-performance RoCE and AI data center networks, our connectivity solutions deliver reliable high-speed data transmission, stable link performance, and seamless integration across demanding network environments.

NVIDIA/Mellanox (Ethernet) 920-9N42F-00RI-3C1, MSN4700-WS2FC, 900-9X81E-00EX-ST0, MCX75310AAS-NEAT, B3240, MCX623105AC-VDAT
Arista 7060XE7-128PE, 7060X6-64PE, 720R4-128PE, 7060DX5-32, 7050DX4-32S, 7280DR3A-54
Juniper QFX5240-64QD, QFX5700, QFX5220-32CD, QFX5120-48T, QFX5110-32Q
Cisco N9164E-NS4-O, N9364E-SG2-Q, Nexus 9364D-GX2A, Nexus 9504, 8501-SYS-MT, Nexus 3432D-S, N9K-X9400-16W(200G)
Broadcom P1800GO, BCM957608-P1400GDF00, BCM957508-N1200G
HUAWEI CE9875-64EO, CloudEngine 16804, CloudEngine 9865-4C, CloudEngine S6780-H4Z, CloudEngine 6885-48YS8CQ-T
H3C S9827-64EP, S9857-24DH8EP, S9855-32D, S9820-8C
Nokia 7220 IXR-H5-32D, 7220 IXR-H2

Questions & Answers

O112-800G-DR4: Frequently Asked Questions

Q: Why choose the O112-800G-DR4 when upgrading to 1.6T networks?

A: The O112-800G-DR4 is designed to connect NVIDIA ConnectX-8 800G NICs to compatible 1.6T Ethernet switches, allowing existing 800G NIC infrastructure to be integrated into a next-generation switching architecture without necessarily replacing the NICs. This approach can simplify network upgrades and help optimize switch-port utilization, transceiver deployment, and fiber cabling. In a specific 288-server cluster design, the projected savings may reach up to 50% in switch count, 37.5% in optical transceiver quantity, and 50% in fiber cabling compared with a conventional 800G switch architecture. These figures are topology-dependent estimates rather than guaranteed results; actual savings depend on port allocation, oversubscription, redundancy, and network design.

Q: Why are there two versions of 800G OSFP112 DR4 transceivers?

A: The O112-800G-DR4 and O112-800G-DR4T share the same core optical and electrical architecture but use different thermal and housing designs for different host applications. The O112-800G-DR4 features a Flat Top housing and is primarily intended for ConnectX-8 NIC applications, where the NIC cage and host cooling system provide the required thermal management. The O112-800G-DR4T uses a Closed Finned Top housing with integrated heat sink fins and is intended for compatible OSFP switch ports that require this module-level cooling design. Always select the housing version specified for the host device.

Q: Which networking scenarios in NVIDIA B300 and GB300 NVL72 systems require the O112-800G-DR4 transceiver?

A: The O112-800G-DR4 is intended for the server/NIC side of compatible network architectures, connecting NVIDIA ConnectX-8 800G NICs to supported 1.6T Ethernet switches, including compatible TH6-based platforms and NVIDIA Spectrum-6 switches. It can be used in RoCE network designs for NVIDIA B300 and GB300 NVL72 AI infrastructure, subject to the system’s supported NIC, switch, port, and firmware configurations.

Q: Which 800G transceiver should I choose for connecting NVIDIA ConnectX NICs to 1.6T switches?

A: The appropriate transceiver depends on the NIC model and the host-side electrical interface. The O112-800G-DR4 is designed for ConnectX-8 NIC-to-compatible 1.6T switch interconnections. The OSFP-800G-DR4 is intended for ConnectX-9 NIC-to-compatible 1.6T switch interconnections. The O112-800G-DR4 uses 8×100G PAM4 electrical lanes and 4×200G PAM4 optical lanes, with signal processing to support the electrical-to-optical lane-rate conversion. By comparison, the OSFP-800G-DR4 uses 4×200G PAM4 lanes on both the electrical and optical sides. Check the NIC’s optical interface requirements and the switch port specifications before selecting a module.

Q: What are the benefits of using a 3nm DSP in an 800G transceiver?

A: A 3nm DSP process can help reduce chip power consumption and improve integration compared with earlier process generations, subject to the specific DSP design and implementation. In an 800G transceiver, the DSP supports high-speed signal processing and helps maintain signal integrity across demanding electrical and optical interfaces. NADDOD’s O112-800G-DR4 incorporates a Broadcom 3nm DSP and is specified for a maximum power consumption of ≤15W, making it suitable for power- and thermal-conscious AI data center deployments. Actual power and performance comparisons with 5nm solutions should be based on equivalent operating conditions and verified product test data.
x